Olympus EVIS EXERA II 180 SERIES Video System

Flexible Endoscopy System

  1. Home
  2. Flexible Endoscopy System
  3. Olympus EVIS EXERA II 180 SERIES Video System
parallax image
Olympus EVIS EXERA II 180 SERIES Video System

Olympus EVIS EXERA II 180 SERIES Video System

Olympus CV-180 & CLV-180 Evis Exera II Endoscopy System

The Olympus CV-180 complete endoscopy system is equipped with a monitor. This helps ensure the best possible image quality for endoscopic and laparoscopic procedures.

This endoscopy tower is compatible with EVIS 100, 130, 140 Series, and EVIS EXERA 160 Series scopes as well as bronchoscopes and surgical endoscopes.

Each component — processor, light source, and monitor fits conveniently into the mobile cart for maximum portability.

Olympus CV-180 & CLV-180 Evis Exera II Endoscopy System Features:

CV-180 Evis Exera II Video Processor.

  • Equipped with high-resolution HDTV imaging capability to assure the best possible image quality for endoscopy and laparoscopy.
  • This enables enhanced observation of capillaries. – Compatible with EVIS 100/130/40 Series and EVIS EXERA 160 Series scopes as well as bronchoscopes and surgical endoscopes (EndoEYE, 1CCD/3CCD Camera Head, and VISERA videoscopes).
  • Narrow Band Imaging (NBI) to enhance the visibility of fine capillaries and the mucosal tissues.
  • Two types of structure enhancement are available – the original Type A for observation of larger mucosal tissues with high contrast, and the new Type B for observation of smaller tissues, such as capillaries.
  • Electronic magnification enlarges moving or still images by 1.2x or 1.5x with no loss of quality.
  • Convenient recording of both still and moving images on xD cards or digital video cassettes using remote control switches. HD/SD SDI output for deterioration-free images.
  • An automatic iris eliminates the need for switching between peak and average required in conventional manual adjustment.

CLV-180 Xenon Light Source:

– Equipped with specially coated filters for NBI.
– Automatically switches off when the unit has not been used for an extended period of time.
– Automatically adjusts the light intensity to achieve ideal illumination for observation of the gastrointestinal tract.
– Powerful 300-watt xenon lamp.
– Backlit front panel indicators and controls improve operability.

Olympus 180 series Video scope:

Olympus Gastroscope GIF-Q180

The EVIS EXERA II GIF-Q180 gastrovideoscope combines high-quality imaging with a slim design. With an insertion tube that is a mere 8.8 mm, it is ideal for a wide range of applications in the upper gastrointestinal tract, from observation to treatment.

● Outstanding image quality: The scope delivers crisp, clear images and life-like color rendition in easy-to-view large display size.
● Slim design: The scope's insertion tube features an 8.8 mm diameter along its entire length for improved insertion capability.
● Scope ID function: The GIF-Q180 store's individual scope information in the built-in memory chip and displays it on the monitor, facilitating endoscopy suite management.

Olympus Colonoscope CF-Q180AL/I

The EVIS EXERA II CF-Q180AL/I colono videoscope features high-resolution, full-screen images, and a forward water jet to facilitate cleaning. For improved handling, innoflexTM Variable Stiffness technology enables adjustment of the insertion tube flexibility, and a generous 3.7 mm diameter channel (12.8 mm diameter insertion tube) accommodates a wide range of endoscopic devices while preserving satisfactory suction capability.

● High-resolution, wide-angle images: High-resolution images feature an extra-wide 170° field of view in a large-size display for detailed examination of the colon.
● Easy mucosal cleaning for better observation: An auxiliary water function can be combined with a dedicated flushing pump to enable removal of mucus and clots in the colon at the touch of a switch on the scope or on the footswitch unit.
● Improved handling: The CF-Q180AL/I features innoflexTM Variable Stiffness technology, enabling adjustment of the insertion tube flexibility to match the conditions and contours of the colon.

Olympus ERCP scope TJF-Q180V

Main Features of TJF-Q180V:

  1. Unique dual locking mechanism for efficient short guidewire exchange in combination with dedicated V-System ERCP devices.
  2. High image quality with exceptionally sharp, crisp details, and large monitor display size.
  3. Narrow Band Imaging enhances observation of the mucosa and capillaries.
  4. Slim 11.3 mm insertion tube.
  5. Wide 4.2 mm diameter channel.
  6. Four-way angulation (120° Up, 90° Down, 110° Right, and 90° Left) facilitates an approach to the papilla of Vater.
  7. Fully compatible with the CV-160 and 140; the use of CV-180 enables the full feature set.
  8. Scope ID function stores individual scope information in the built-in memory chip and displays it on the monitor.

Olympus Bronchoscope BF-Q180

EVIS EXERA II BRONCHOVIDEOSCOPE EVIS EXERA II BRONCHO VIDEOSCOPE OLYMPUS BF TYPE Q180 OLYMPUS

Main Features:

  • Superior image quality and a larger image size redefine examination and treatment in the bronchial tree.
  • Narrow Band Imaging capability to highlight hidden tissue structures.
  • Despite superior image quality, this scope features a slim design — measuring 5.1 mm in diameter at the insertion tube and 5.5 mm in diameter at the distal end.
  • Standard 2.0 mm diameter channel to accommodate a wide variety of endo-therapy accessories.
  • BF -Q180 — A stunning new level of imaging performance in bronchoscopy
  • Compatible with electrosurgical and laser devices.
  • Fully compatible with the Olympus CV-180 (CV-160/140) video processor and CLV-180 light source.
  • Scope ID function stores individual scope information and displays it on the monitor to help facilitate management in pulmonary labs and operating rooms.
  • Specifications Light Guide lens Optical System Field of view 120 ̊ Direction of view 0 ̊ (Forward viewing) Depth of field 3 ~ 100 mm Insertion Tube Distal end outer diameter 5.5 mm Insertion tube outer diameter 5.1 mm Working length 600 mm Instrument Channel Channel inner diameter 2.0 mm Minimum visible distance 3 mm from distal end Endo therapy accessory entrance/exit position in field of view Bending Section Angulation range UP 180°, DOWN 130 ̊
  • Laser Compatibility Nd: YAG, 810nm diode Electro-Cautery Instrument Compatibility YES Total Length 870 mm Instrument Channel outlet Objective lens Light Guide lens Ancillary product CV-180 Video System Center Designed to accommodate a wide range of scopes from a myriad of specialties, this leading-edge video processor offers high-resolution images and state-of-the-art image processing capabilities such as Narrow Band Imaging as well as a range of practical digital solutions.
  • CLV-180 Xenon Light Source With its powerful 300-watt xenon lamp, this light source unit delivers brilliant, shadow-free illumination and is equipped with filters that have been specially coated for use in Narrow Band Imaging. A new button on the front panel lets you turn the lamp on or off without having to power down the light source unit itself. Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer.